Tinned copper mesh and braid reestablish the metallic shielding across the joint. We also have joints for 3 core pilc, transition versions and trifurcating versions up to 193336kv. A study of a mv cable joint sjee serbian journal of. Quickbits swa cable joints are supplied with everything needed to join two or even three cables together. All kits contain a clear pvc joint shell which snaps together with a clip on cover for the central filling hole. Please call the office on 01244 2888 for more information or advice. The medium voltage cable jointing range includes the tyco electronics heat shrink straight joints for nonarmoured and wire armoured polymeric power cables, the all in one cold applied joint for single core nonarmoured polymeric cables and the heat shrink nonresin joint. With an extensive range of products from industry leading manufacturing brands such as 3m, abb, lovink and te connectivity tyco electronics, jointing tech are your single source to deliver all your mv cable joint solution needs on time and within budget. A study of a mv cable joint 5 conducting materials, was found to produce an extremely high total field at certain points and thus obstruct the quality of the joint. The aim of a cable jointer must therefore to be to obtain a joint whose electrical properties are as good as the original cable both in electrical and mechanical terms. Testing contact resistance of terminations for signs of deterioration. The purpose of a cable jointer is to lay, joint, terminate and repair underground power cable, they essentially lay new power cables through underground pipes and terminate them at electrical equipment. Perfect quality and meet the customers requirements.
Hai, welcome the sharing from experienced minds the best methode of ht cable jointing procedure 33kv singlecore copper cable for trifoil. Factors considered for high voltage cable joint design. This invention relates to improved methods of forming cable joints and means therefor, and is particularly applicable to joints in electric power cables and electrical communication wire cables of the types enclosed in lead or. Now hear this nht was founded to produce lowcost loudspeakers a breed apart from the massmarket variety often found at the lower price points. Practical hv cable jointing and terminations for engineers. The polyurethane two part resin is supplied in a sealed sachet with a clip seperating the resin and hardner. These joints are designed for compression connection, mechanical connectors or soldering of cable conductors. Cable jointing supplies high voltage and low voltage. Cable jointing is a necessary part of daily life for electrical engineers, and high expectations are placed on the end result. Joint box for cat 5e and cat 6 utp cables 110 punch down terminations designed to cause minimal impact on cabling performance compact, surface mounting design enables extending of cable runs without recabling supplied complete with fixing screws, double sided adhesive pad and cable ties technical data.
Ends sealed 10 cable exit trench at location indicated on drawing 11 cable joint locations recorded on as build drawings. Consequently, hydrocarbons contaminated the cable via a pathway along the. Mix the resin as instructed on the resin pack and pour into the joint case until the case is. Mix the resin as instructed on the resin pack and pour into the joint case until the case is completely full. Product note kabeldon cable joint, 52123 kv jsa, jxa two types of cable joints are available. A wide variety of 3 types cable joints options are available to you, such as conductor material, type, and application. Making a joint for a paper insulated cable 1932 youtube. Joints manufacturing and installation should be economical. The design of cable jointing and termination accessories is based on this perception. The joint is applicable to various types of cable screens and cable sheaths. However, it remains a symmetric and enclosed design. Lv cable jointing and heat shrink ets cable components. Insulating tubing and semi conducting tubing reinsulate and reshield the areas over the spliced conductors.
Written policies and procedures are essential to the effective and efficient operations of your programs and organization. Welding can be carried out with matching fillers similar in composition to the base material. The idea of having conducting or semiconducting parts in the joint was tested based on some earlier designs of high voltage cables 4. The nht operates its mobile office from linstead, papine and portmore on tuesdays, wednesday and saturdays, respectively.
Shrink polymer systems for heatshrink cable joints and. The molding is done in the factory, reducing onsite time. When considering a sample policy or procedure, be sure to read them thoroughly and make appropriate changes to ensure they match your organizational needs. Inspect exposed sections of cables for physical damage. The national housing trust, nht, wishes to advise that it has temporarily suspended its nht mobile operations immediately. Inspect bolted electrical connections for high resistance using one of the following methods. Including resin filled, heat shrink and cold shrink products available from 3m and birkett.
Cable joints are a cost effective way of reducing the time which is lost in the process of electrical cable jointing. Product note kabeldon cable joint, 52123 kv jsa, jxa. The aim of a cable jointer must therefore be to obtain a joint whose electrical properties are as good as the original cable both in electrical and mechanical terms. We are also contactable by email if your enquiry is out. Medium voltage mv cable joints jointing technologies. Typicallowerhalfofjointcaseplanview branchcable bedding steelwirearmour maincable 10 x 20 5 leadsheath bedding 5 2 x 10 typicaljointcasebottomhalf. Low voltage cable joints, oversleeving and cable jointing accessories. Visual inspection of cable joints, splices and ground connections for integrity and condition and cleaning of termination joint outer surfaces of dust and contaminant deposits. The only search engine that helps you share socially. Xlpe cable at different locations between new haldia.
Through joint for xlpe cable cabseal heat shrink joint consist 3 layer insulating reinforcementcabseal heat shrink joint consist 3 layer insulating reinforcement. Joints design must have high degree reliability, good thermal performance. Nht warrants that if our product fails to function properly under normal use due to a manufacturing defect when installed and operated according to the owners manual instructions enclosed with the unit, it will be repaired or replaced with. The welding metallurgy of nht nonheat treatable alloys is fairly simple since there is no precipitation reactions involved and are not prone to hot cracking or solidification cracking. A cable joint protects cables against moisture ingress. Cable joint and method of forming same cons edison. Stress control tubing to control the stress developed at cut point in semi conducting layer. Sterling power cable jointing training manual by phd. Up to 10 days jointing instructions and procedures cable handling and stripping.
Cofounder ken kantor has a long history in the hifi business as a designer at acoustic research, nad, and as a design consultant to some large japanese manufacturers. In addition, aspects of its marketing activities have been placed on hold until further notice. Insulation test between conductors, and resistance to. Insulating tubing for better electrical insulation control. The power cable joint has basically a similar structure as a power cable, except that its dimension changes along the length. Hence for high voltage application the slipon procedure is still the preferred way to install the joint. The cast resin system provides the electrical insulation, mechanical protection and moisture imperviousness to the joint. Compare cable data with drawings and specifications. This is a video we recently made of our heat shrink joint for 3 core 6. Resin joints, heat shrink joints, cold shrink joints, cable lugs, terminals, crimp tools, cet glands, traffic signal feeder pillars, single and double pole street lighting cut outs and isolators, slot cutting resins, reenterable resins, cabinet base sealants. Premolded housing void free joint housing consists of cured epdm insulation bonded under pressure to cured molded semiconductive elements.
Pictured opposite is a heat shrink cable joint failure caused by the jointer not providing adequate connection of the earth continuity across a jointed shipwiring braided type cable. About 3% of these are terminals, 43% are connectors, and 0% are power cables. What are the maintenance procedures for underground. Types of cable to be joined, cablejoint body interface, cable system voltage and voltage. The quality of a joint or termination depends to a large extent on the skill of cable jointer. Contractor shall take back all the cable drums from site after successful laying, testing and commissioning of cables. Conclusion cable joints are the weakest links in cable systems.
1325 1212 121 541 380 3 188 1355 50 1631 1471 1106 723 671 456 610 1558 3 936 1044 1216 860 318 1394 324 206 1345 261 503 1212 279